jonny_l480 50ee4244d3 Fix bat voltage: lookup table, currentSensors: Add snap to zero
display.cpp:
    Optimize battery voltage measurement
    While calibrating noticed it is very non-linear
    - outsource function to scale using lookup table
    - add lookup table to batvoltage measurement
      inserted many values to lookup table while testing

currentsensors:
    Fix current value jumping around between 0 and 0.2 on display
    while standstill
    - add parameter snapToZeroThreshold